High Temperature FKM FRW CABLE Flexible Fluoropolymer Cable is engineered for demanding automotive and industrial wiring harnesses requiring long-term thermal endurance, high-temperature fluid resistance, and fluid blocking at a cost-effective harness design.
High Temperature High Humidity FRW-ST Cable is a flexible fluoropolymer automotive wire engineered for harsh thermal and wet operating environments. CITCABLE has meet now requiring 160°C 10,000 hour heat age test. It has a life expectancy over 12,000 hours at 150°C and 24,000 hours at 125°C.
The end result is an automotive wire ideally suited in applications where heat protection, high temperature fluid resistance, fluid blocking, long life and less expensive wiring harness are required.
We provide flexible fluorpolymer frw-st cable products. If you are interested in flexible fluorpolymer frw-st cable, please contact us and initiate a consultation for more information.
| Feature | Description |
|---|---|
| High Temperature Endurance | Rated from -40°C to 200°C and meets 160°C 10,000-hour heat age test requirements for long-term thermal stability. |
| Extended Service Life | Provides a life expectancy of over 12,000 hours at 150°C and over 24,000 hours at 125°C. |
| High Humidity Resistance | Engineered to maintain stable electrical insulation performance in high-humidity and moisture-prone environments. |
| High Temperature Fluid Resistance | Offers strong resistance to automotive oils, coolants, fuels, and chemical fluids at elevated temperatures. |
| Fluid Blocking Capability | Helps prevent liquid migration and wicking through the wiring harness to protect connected components. |
| Flexible Fluoropolymer Construction | Combines fluoropolymer protection with flexibility for easier routing in compact automotive harnesses. |
| Cost-Effective Harness Solution | Delivers long-life heat and fluid protection while supporting less expensive overall wiring harness designs. |
FRW-ST flexible fluoropolymer cable consists of fully annealed stranded copper conductors insulated with a specialized flexible fluoropolymer layer. Depending on the harness design, optional fluid-blocking features or multi-core arrangements can be specified to meet application requirements.

| Layer | Material | Function |
|---|---|---|
| Conductor | Fully annealed stranded copper (Per ASTM B-33) | Provides reliable electrical conductivity and flexibility for automotive harness routing. |
| Insulation Layer | Flexible Fluoropolymer (FRW-ST) | Provides electrical insulation (600V DC), heat aging protection, high-humidity resistance, and fluid resistance. |
| Fluid Blocking Design (As Required) | Integrated blocking structure | Helps prevent liquids from wicking along the conductor strands into connectors or control modules. |
Note: The final cable construction depends on the selected conductor cross-section, insulation wall thickness, and harness specifications. Exact structure details should be confirmed before production.
Automotive engine compartments and powertrain zones expose wiring harnesses to continuous heat, high humidity, and hot fluids. FRW-ST flexible fluoropolymer insulation is designed to maintain long-term electrical and mechanical integrity where conventional automotive wire insulation may degrade prematurely.
When Insulation Is Not Suitable for the EnvironmentContinuous Heat / High Humidity / Hot Automotive Fluids Potential concerns:
|
With FRW-ST Flexible FluoropolymerFlexible Fluoropolymer Insulation & Fluid Blocking Material advantages:
|
Actual cable performance depends on conductor size, insulation dimensions, installation routing, and the specific operating environment.
The following table summarizes the technical specifications for High Temperature High Humidity FRW-ST Cable. Final parameters should be confirmed according to your wiring harness design and application.
| Item | Specification |
|---|---|
| Rated temperature | -40°C ~ 200°C |
| Rated voltage | 600V DC |
| Conductor | 0.1mm² to 10.0mm² fully annealed stranded copper Per ASTM B-33 |
| Insulation Material | Flexible Fluoropolymer (FRW-ST) |
| Heat Age Test | 160°C for 10,000 hours |
| Thermal Life Expectancy | Over 12,000 hours at 150°C; over 24,000 hours at 125°C |
Note: Conductor standard ASTM B-33 applies to the stranded copper conductor specification. Complete cable testing and qualification requirements should be confirmed based on the specific order.
FRW-ST cable is designed for automotive and industrial applications where long-term heat aging, high humidity, and fluid exposure must be evaluated together. The following thermal endurance values are based on the supplied product information.
| Environmental / Thermal Item | Specified Condition / Performance |
|---|---|
| Heat Age Test Requirement | 160°C for 10,000 hours |
| Life Expectancy at 150°C | Over 12,000 hours |
| Life Expectancy at 125°C | Over 24,000 hours |
| Operating Temperature Range | -40°C to 200°C |
| Humidity & Fluid Protection | High humidity endurance, high-temperature fluid resistance, and fluid blocking |
Important: Actual service life depends on continuous operating temperature, fluid composition, mechanical vibration, and harness installation conditions. Suitability for specific automotive OEM standards should be confirmed against project requirements.
FRW-ST flexible fluoropolymer cable is ideally suited for automotive and industrial wiring applications requiring heat protection, high-temperature fluid resistance, fluid blocking, and long service life.
| Application Area | Relevant Requirements |
|---|---|
| Automotive Engine Compartments | Wiring harnesses exposed to sustained high temperatures, oils, coolants, and engine fluids. |
| Transmission & Powertrain Harnesses | Applications requiring high-temperature fluid resistance and fluid blocking to prevent wicking. |
| High-Humidity Automotive Zones | Under-hood and chassis wiring where moisture and high humidity require durable insulation. |
| EV / HEV & Industrial Wiring | Flexible 600V DC wiring requiring long thermal life and cost-effective harness assembly. |
Application suitability should be assessed using the actual service temperature, fluid exposure, electrical load, and installation conditions.
Different automotive wiring harnesses and equipment designs require specific conductor sizes, insulation dimensions, and color coding. FRW-ST flexible fluoropolymer cable can be configured according to your project specifications.
| Customization Item | Available Design Considerations |
|---|---|
| Conductor Size | Selection within the specified range of 0.1mm² to 10.0mm² fully annealed stranded copper. |
| Cable Configuration | Single-core or multi-core configurations, subject to design and production confirmation. |
| Insulation Color | Standard automotive colors or custom color coding for harness identification. |
| Insulation Dimensions | Wall thickness and outer diameter customized to match connectors and seals. |
| Cable Marking | Custom printing and identification, subject to availability. |
| Cable Length & Packaging | Customized spool lengths and packaging for automated harness processing. |
To discuss a customized FRW-ST cable, please provide the conductor size, number of cores, required outer diameter, voltage rating, operating temperature, and fluid exposure details. Technical drawings or existing specifications are also welcome.
Automotive and high-humidity wiring projects require precise control over conductor stranding, fluoropolymer extrusion, and fluid-blocking performance. Clear technical communication helps ensure the cable matches your harness assembly requirements.
Note: Specific production capabilities, available configurations, customization limits, and documentation services should be confirmed with the manufacturer before quotation.
For high-temperature, high-humidity automotive wire applications, inspection requirements should be determined by the cable design and intended service conditions. The following items can be considered when preparing a project-specific inspection plan.
| Inspection Item | Purpose |
|---|---|
| Conductor Inspection | Review conductor material, stranding, cross-section, and resistance per ASTM B-33. |
| Dimensional Inspection | Check insulation wall thickness and overall outer diameter against the approved specification. |
| Electrical Testing | Evaluate dielectric withstand and insulation resistance for 600V DC rating requirements. |
| Heat Aging Evaluation | Assess long-term thermal endurance (such as 160°C 10,000-hour heat age requirements). |
| Humidity & Fluid Resistance Evaluation | Evaluate insulation compatibility with high humidity and specified automotive fluids. |
| Fluid Blocking Verification | Check fluid-blocking performance against the agreed test method where required. |
These are potential project inspection items, not a statement that every test is routinely performed on every cable. Test availability, standards, methods, and acceptance criteria should be agreed before production.
FRW-ST cable has a rated temperature range of -40°C to 200°C. It meets the 160°C 10,000-hour heat age test requirement and offers a life expectancy of over 12,000 hours at 150°C and over 24,000 hours at 125°C.
The cable uses 0.1mm² to 10.0mm² fully annealed stranded copper conductors conforming to ASTM B-33.
It combines heat protection, high-temperature fluid resistance, fluid blocking, and long service life in a flexible fluoropolymer design, helping achieve a reliable and less expensive wiring harness solution.
The supplied specification states a rated voltage of 600V DC. Specific electrical requirements for your system should be confirmed during technical consultation.
Yes. Conductor size, core configuration, insulation color, outer diameter, cable marking, and spool length can be discussed based on your project requirements, subject to technical and production confirmation.
Please provide your required conductor size (mm² or AWG), number of cores, outer diameter, color, operating temperature, fluid exposure conditions, and estimated quantity. Drawings or existing specifications are also helpful.